| Inclusions | AS2047: Express Test NAS021 |
AS2047: Standard Test NAS022 |
AS2047: Optimised Test NAS023 |
||
|---|---|---|---|---|---|
| Complete AS2047 Test Sequence | ![]() |
![]() |
![]() |
||
| NATA-accredited report | ![]() |
![]() |
![]() |
||
| Pre-booked time slot | Within 20 Business Days |
![]() |
![]() |
||
| Private Booking Availability | ![]() |
Private Booking |
Private & Priority Booking |
||
| Re-test Upon Failure | Re-testing not available. |
One Re-test - Time Allowing |
Up to two additional attempts or repairs per product, regardless of pass or fail outcome. |
||
| Re-test Upon Passing | Re-testing not available. |
Optional Paid Re-Test: NAS024 |
Up to two additional re-tests or repairs per product, regardless of pass or fail outcome. |
||
| Pre-test Design Review | Optional Paid Add-on: STS008 |
Optional Paid Add-on: STS008 |
![]() |
||
| Oversized Specimen (Over 7.2sqm) |
No Option For Oversized Testing |
Oversize Option: NAS012 |
Oversize Option: NAS013 |
||
| AS5203: Kid’s Don’t Fly | Optional Paid Add-on: STS007 |
Optional Paid Add-on: STS007 |
Optional Paid Add-on: STS007 |
||
| Window Energy Ratings (U-Value & SHGC) |
Optional Paid Add-on: WERS01 |
Optional Paid Add-on: WERS01 |
Optional Paid Add-on: WERS01 |
||
| What To Expect | |||||
| Select Inclusion | |
| Pre-test Design Review | |
| Complete AS2047 Test Sequence | |
| NATA-accredited test report to AS2047 | |
| Pre-booked time slot | |
| Private Booking Availability | |
| Oversized Specimen Compatibility | |
| AS5203: Kid’s Don’t Fly | |
| WERS | |
| Re-test Upon Failure | |
| Re-test Upon Passing | |
| What To Expect |


| Project Type | Builder Std. Dwelling NAT001 |
Designer Dwelling NAT002 |
Architectural Dwelling NAT003 |
Dual Occupancy NAT004 |
|---|---|---|---|---|
| Description | Builder-led, template, volume-built, or minor renovation | Designer-led, bespoke homes, major alterations & additions | Architect-led, large/complex architectural homes | Two dwellings on same lot, e.g. duplex |
| Storeys Included | Single & double storey | Up to 3 storeys | Up to 3 storeys | Single & double storey |
| NatHERS Certificate | ![]() |
![]() |
![]() |
![]() |
| Whole-of-Home Assessment | ![]() |
![]() |
![]() |
![]() |
| Architectural Drawing Revision | Remodelling as a result of drawing revisions charged seperately |
Remodelling as a result of drawing revisions charged seperately |
Remodelling as a result of drawing revisions charged seperately |
Remodelling as a result of drawing revisions charged seperately |
| Typical Turnaround | Two Weeks | Two - Three Weeks | Four Weeks | Two - Three Weeks |
| Select Inclusion | |
| Description | |
| Storeys Included | |
| NatHERS Certificate | |
| Whole-of-Home Assessment | |
| Architectural Drawing Revision |
| Part Code | Service |
|---|---|
| NAS051 | AS 4145 Latching Durability Testing — Up to 100,000 Cycles |
| NAS052 | AS 4145 Deadlocking Durability Testing — Up to 50,000 Cycles |
| NAS053 | AS 4145 Key Operation Durability Testing — Up to 50,000 Cycles |